  ABC TYPE FIRE EXTINGUISHER  
  Store Pressure ( Multipurpose Fire Extinguisher )  
 
"THIS BRAND" BIS APPROVED ISI MARK ABC TYPE FIRE EXTINGUISHER COVERS A,B,C CLASS OF FIRES WHICH INCLUDE PAPERS, WOOD, CLOTH RUBBER, PLASTIC & INFLAMMABLE LIQUID LIKE OIL, PETROL, PAINTS, PETROCHEMICAL PRODUCT, RESINS, GASES IN THE COMPRESSED FROM ACETYLENES, LPG & CNG, ELECTRICAL & SOPHISTICATED ELECTRICAL EQUIPMENT.
 
 
 
  Technical Specification :  
     
 
Capacity (in Kg)
500 gm
1
2
5
10
IS Specification
13849
13849
13849
13849
13849
Jet Range (In Mtr.)
1.5
2-4
2-4
4-5
<6
Discharge Time (In Sec.)
6-8
8-10
8-10
15-20
23-30
Min. Discharge Quantity
85%
85%
85%
85%
85%
Seal of Approval
ISI
ISI
ISI
ISI
ISI
Hydraulic Test Pressure of Cylinder (Kg./Cm2)
30
30
30
30
30
Discharge Outlet
Direct Nozzle
Direct Nozzle
Direct Nozzle
Direct Nozzle
Direct Nozzle
 
  WATER CO2 TYPE FIRE EXTINGUISHER FOR "A" CLASS OF FIRE  
 
"THIS BRAND" BIS APPROVED ISI MARK ABC TYPE FIRE EXTINGUISHER & WATER STORE PRESSURE TYPE PROVIDES SAFETY AGAINST "A" CLASS OF THE FIRE WHICH INVOLVES MATERIAL LIKE WOOD, PAPER, CLOTH, PLASTICS & FIBER, RUBBER ETC.
 
 
CAUTION : NOT TO BE USED ON ELECTRICAL FIRES
 
 
 
 
Technical Specification
Water CO2 Store Pressure
Water CO2
Water CO2
Capacity (In Ltr.)
9
9
50
IS Specification
6234
940
13385
Jet Range (In Mtr.)
<6
<6
10
Discharge Time (In Sec.)
60-90
60-120
60-180
Min. Discharge Quantity
95%
95%
90%
Seal of Approval
ISI
ISI
-
Hydraulic Test Pressure of
Cylinder (Kg./Cm2)
30
30
30
 
  DRY CHEMICAL POWDER TYPE FIRE EXTINGUISHER FOR "B" & "C" CLASS OF FIRE  
 
"THIS BRAND" BIS APPROVED ISI MARK DRY CHEMICAL FIRE EXTINGUISHER CONTROL B & C CLASS OF FIRE LIKE OIL, PETROL AND PETROLEUM PRODUCT, SOLVENT, PAINTS, VARNISHES, CHEMICAL LIQUIDS, ALL FLAMMABLE LIQUIDS & ELECTRICAL FIRE & GAS FIRE, ETC.
 
 
 
 
Technical Specification
Capacity (In Ltr.)
5
10
25
50
75
IS Specification
2171
2171
10658
10658
10658
Jet Range (In Mtr.)
4-5
<6
<6
8-10
10-12
Discharge Time (In Sec.)
15-20
25-30
25-30
40-50
50-60
Min. Discharge Quantity
90%
90%
85%
85%
85%
Seal of Approval
ISI
ISI
-
-
-
Hydraulic Test Pressure of Cylinder (Kg./Cm2)
30
30
30
30
30
 
  CARBON DIOXIDE TYPE FIRE EXTINGUISHER FOR "B" & "C" CLASS OF FIRE  
 
"THIS BRAND" CARBON DIOXIDE TYPE FIRE EXTINGUISHER ARE SUITABLE FOR B & C CLASS OF FIRES INVOLVING ALL FLAMMABLE LIQUIDS, GASES, LIVE & DELICATE, MACHINERY FIRES, ELECTRICAL & SOPHISTICATED ELECTRONIC EQUIPMENTS FIRES TRASNFORMER & SWITCH GEAR FIRE. THIS EXTINGUISHER IS APPROVED BY EXPLOSIVE DEPARTMENT, GOVT. OF INDIA, NAGPUR
 
  THE NEW CO2 SQUEEZE GRIP TYPE PORTABLE FIRE EXTINGUISHER ALSO AVAILABLE  
 
 
 
Technical Specification
Capacity (In Kg.)
2
3
4.5
6.5
9
22.5
IS Specification
2878
2878
2878
2878
2878
2878
Jet Range (In Mtr.)
2
2
2.5-3
2.5-3
2.5-3
2.5-3
Discharge Time (In Sec.)
14-16
16-18
20-24
25-30
30-35
50-60
Min. Discharge Quantity
98%
98%
98%
98%
98%
98%
Hydraulic Test Pressure of Cylinder (Kg./Cm2)
250
250
250
250
250
250
Working Pressure (Kg./Cm2)
60-65
60-65
60-65
60-65
60-65
60-65
 
  MECHANICAL FOAM (AFFF) FIRE EXTINGUISHER FOR "A" & "B" CLASS OF FIRE  
 
"THIS BRAND" MECANICAL FOAM TYPE FIRE EXTINGUISHER IS DESIGNED TO EXTINGUISH A & B CLASS OF FIRE INVOLVING WOOD, PAPER, CLOTH, TEXTILE, STATIONERY & VERY SPECIAL BLANKET EFFECT ON FLAMMABLE & VOLATILE LIQUIDS LIKE OIL, PETROL, KEROSENE, SOLVENT & CHEMICAL, WAX, RESINS ETC.
 
  CAUTION : NOT TO BE USED ON ELECTRICAL FIRES  
 
 
 
Technical Specification
MECH.FOAM
MECH.FOAM
MECH FOAM STORE
PRESSURE
Capacity (In Kg.)
9
50
9
IS Specification
10204
13386
15397
Jet Range (In Mtr.)
<6
10
<6
Discharge Time (In Sec.)
60-90
60-180
25-60
Min. Discharge Quantity
95%
90%
90%
Hydraulic Test Pressure of Cylinder (Kg./Cm2)
30
30
30
 
  AUTOMATIC MODULAR FIRE EXTINGUISHER A B C E CLASS OF FIRE  
  Contents: Automatic ABC Dry Power, Dry Chemical Powder, FM-200 etc.  
 
Operation: When heat from an uncontrolled fire increases to a pre-set temperature of the unit, the fusible link releases discharging the extinguishing agent. The releases temperature of the extinguisher (fusible link) can be preset at works ranging from 570c/680c/790c/930c/1400c and so on. They require no external source of energy and it can be operated electrically, manually or mechanically for their-operation.(Optionally)
 
 
Applicability for General Occupancies & Storage Areas like : Storage of Flammable & Combustible Liquids & Gases, Chemicals, Grain Mill Products, Solids Fuels, Records, Libraries, Museums, Showrooms, Shops, Offices, Residential premises, Workshop, Garages, Paint Booths, Theatre, Radio Rooms TV Stations etc.
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Shah Industrial Products
Office No. 123, 1st Floor, Ashapura Complex, Near Telephone Exchange, Char Rasta, GIDC, VAPI - 396195. Gujarat-INDIA.
Telefax : +91-260-2422322, Cell : +91-9824506011, 9824031011
E-mail : response@shahfiresafety.in, shahindpro@gmail.com, shahindrpro@yahoo.co.in